WHY USE OIL IN YOUR HYDRAULIC SYSTEM WHEN WILL DO THE JOB ? |
| |
Since the late 1980's the products of The Water Hydraulics Co. have
been employed in a wide variety of applications throughout the world.
Although the initial cost of the product is higher than conventional drive systems, the operating and through life costs can demonstrate substantial savings and benefits. |
| |
The Water Hydraulics Company is a manufacturer of components and systems that operate on tap water without any other fluid additives. |
| |
| The products are also appropriate for operation on technical water and with consideration sea water. The company is ISO 9001-2000 accredited ensuring the level of quality that is dictated by the markets served. |
| |
Operating in similar pressure ranges to conventional hydraulics, water systems can offer greater efficiencies reducing operation costs and minimising component size.
High linear and rotary power is achieved from compact designs without risk of fire or contamination to the environment, the product or the person using the equipment. The products are designed to existing oil hydraulic interfaces ensuring minimal engineering for interchange ability. |
| |
A full range of components are produced by the company, supplied in component or total system form, including bespoke designs to customer specification. |
| |
By making a risk assessment of your system or product driven by water hydraulics compared to a conventional drive the advantages of the technology can be seen, especially where the Health and Safety implications are considered. |
| |
 |
|
 |
| |
|
|
| Pumps |
 |
TYPE |
|
P1 |
P6 |
P15 |
P30 |
P60 |
P180 |
Displacement cc/ rev |
Max
Min |
1.5
0.8 |
6
3.3 |
19
8 |
33
20 |
70.3
35 |
225
104 |
Max RPM--unboosted
Boosted* |
|
2000 |
1800
2000 |
1800
2000 |
1800
2000 |
1800
2000 |
1800
2000 |
Max Input Power( kw ) |
|
0.55 |
3.8 |
11 |
19.5 |
42 |
114 |
Max.cont.pressure (bar ) |
|
120 |
160 |
160 |
160 |
160 |
160 |
Max.water flow ( l / min ) |
|
2.4 |
12 |
37.2 |
66 |
146 |
430 |
Weight-- Kgs |
|
1.5 |
2.2 |
8.0 |
10 |
19 |
82 |
Temperature *C |
Max**
Min*** |
50
2 |
50
2 |
50
2 |
50
2 |
50
2 |
50
2 |
|
|
| |
| Motors |
 |
TYPE |
|
M3 |
M6 |
M15 |
M30 |
M60 |
M180 |
Displacement
cc / rev |
Max
Min |
3.1
- |
6
4.6 |
19
15 |
33
30 |
70.3
63 |
225
104 |
RPM |
Minimum
Maximum |
500
4000 |
500
4000 |
500
4000 |
500
4000 |
500
4000 |
300
2000 |
Max. ower ( KW )cont. |
|
2.7 |
5.4 |
17.5 |
31 |
67 |
108 |
Max. Pressure ( bar ) cont. |
|
160 |
160 |
160 |
160 |
160 |
160 |
Max. Input ( l / min )--cont. |
|
12 |
24 |
72 |
132 |
292 |
430 |
Weight in KGS-- |
|
1.6 |
2.2 |
8.0 |
10 |
19 |
82 |
Temperature |
Max
Min |
50
2 |
50
2 |
50
2 |
50
2 |
50
2 |
50
2 |
|
|
|